]> code.delx.au - pulseaudio/blobdiff - man/pactl.1.xml.in
pactl: Document ability to specify channel volumes individually
[pulseaudio] / man / pactl.1.xml.in
index 86e76099bf54098b450e9558070960f286f3c56d..a195b1d74523ac68fb864d5ab6fe906ca4b8393b 100644 (file)
@@ -119,8 +119,8 @@ USA.
     </option>
 
     <option>
-      <p><opt>unload-module</opt> <arg>ID</arg></p>
-      <optdesc><p>Unload the module instance identified by the specified numeric index.</p></optdesc>
+      <p><opt>unload-module</opt> <arg>ID|NAME</arg></p>
+      <optdesc><p>Unload the module instance identified by the specified numeric index or unload all modules by the specified name.</p></optdesc>
     </option>
 
     <option>
@@ -162,63 +162,83 @@ USA.
       <optdesc><p>Set the specified card (identified by its symbolic name or numerical index) to the specified profile (identified by its symbolic name).</p></optdesc>
     </option>
 
+    <option>
+      <p><opt>set-default-sink</opt> <arg>SINK</arg></p>
+      <optdesc><p>Make the specified sink (identified by its symbolic name) the default sink.</p></optdesc>
+    </option>
+
     <option>
       <p><opt>set-sink-port</opt> <arg>SINK</arg> <arg>PORT</arg></p>
       <optdesc><p>Set the specified sink (identified by its symbolic name or numerical index) to the specified port (identified by its symbolic name).</p></optdesc>
     </option>
 
+    <option>
+      <p><opt>set-default-source</opt> <arg>SOURCE</arg></p>
+      <optdesc><p>Make the specified source (identified by its symbolic name) the default source.</p></optdesc>
+    </option>
+
     <option>
       <p><opt>set-source-port</opt> <arg>SOURCE</arg> <arg>PORT</arg></p>
       <optdesc><p>Set the specified source (identified by its symbolic name or numerical index) to the specified port (identified by its symbolic name).</p></optdesc>
     </option>
 
     <option>
-      <p><opt>set-sink-volume</opt> <arg>SINK</arg> <arg>VOLUME</arg></p>
+      <p><opt>set-port-latency-offset</opt> <arg>CARD</arg> <arg>PORT</arg> <arg>OFFSET</arg></p>
+      <optdesc><p>Set a latency offset to a specified port (identified by its symbolic name) that belongs to a card (identified by its symbolic name or numerical index).
+      <arg>OFFSET</arg> is a number which represents the latency offset in microseconds</p></optdesc>
+    </option>
+
+    <option>
+      <p><opt>set-sink-volume</opt> <arg>SINK</arg> <arg>VOLUME [VOLUME ...]</arg></p>
       <optdesc><p>Set the volume of the specified sink (identified by its symbolic name or numerical index).
       <arg>VOLUME</arg> can be specified as an integer (e.g. 2000, 16384), a linear factor (e.g. 0.4, 1.100), a percentage
       (e.g.  10%, 100%) or a decibel value (e.g. 0dB, 20dB).  If the volume specification start with a + or - the volume
-      adjustment will be relative to the current sink volume.</p></optdesc>
+      adjustment will be relative to the current sink volume.  A single volume value affects all channels; if multiple
+      volume values are given their number has to match the sink's number of channels.</p></optdesc>
     </option>
 
     <option>
-      <p><opt>set-source-volume</opt> <arg>SOURCE</arg> <arg>VOLUME</arg></p>
+      <p><opt>set-source-volume</opt> <arg>SOURCE</arg> <arg>VOLUME [VOLUME ...]</arg></p>
       <optdesc><p>Set the volume of the specified source (identified by its symbolic name or numerical index).
       <arg>VOLUME</arg> can be specified as an integer (e.g. 2000, 16384), a linear factor (e.g. 0.4, 1.100), a percentage
       (e.g.  10%, 100%) or a decibel value (e.g. 0dB, 20dB).  If the volume specification start with a + or - the volume
-      adjustment will be relative to the current source volume.</p></optdesc> </option>
+      adjustment will be relative to the current source volume.  A single volume value affects all channels; if multiple
+      volume values are given their number has to match the source's number of channels.</p></optdesc> </option>
 
     <option>
-      <p><opt>set-sink-input-volume</opt> <arg>INPUT</arg> <arg>VOLUME</arg></p>
+      <p><opt>set-sink-input-volume</opt> <arg>INPUT</arg> <arg>VOLUME [VOLUME ...]</arg></p>
       <optdesc><p>Set the volume of the specified sink input (identified by its numerical index).
       <arg>VOLUME</arg> can be specified as an integer (e.g. 2000, 16384), a linear factor (e.g. 0.4, 1.100), a percentage
       (e.g.  10%, 100%) or a decibel value (e.g. 0dB, 20dB).  If the volume specification start with a + or - the volume
-      adjustment will be relative to the current sink input volume.</p></optdesc> </option>
+      adjustment will be relative to the current sink input volume.  A single volume value affects all channels; if multiple
+      volume values are given their number has to match the sink input's number of channels.</p></optdesc> </option>
 
     <option>
-      <p><opt>set-source-output-volume</opt> <arg>OUTPUT</arg> <arg>VOLUME</arg></p>
+      <p><opt>set-source-output-volume</opt> <arg>OUTPUT</arg> <arg>VOLUME [VOLUME ...]</arg></p>
       <optdesc><p>Set the volume of the specified source output (identified by its numerical index).
       <arg>VOLUME</arg> can be specified as an integer (e.g. 2000, 16384), a linear factor (e.g. 0.4, 1.100), a percentage
       (e.g.  10%, 100%) or a decibel value (e.g. 0dB, 20dB).  If the volume specification start with a + or - the volume
-      adjustment will be relative to the current source output volume.</p></optdesc>
+      adjustment will be relative to the current source output volume.  A single volume value affects all channels; if multiple
+      volume values are given their number has to match the source output's number of channels.</p></optdesc>
     </option>
 
     <option>
-      <p><opt>set-sink-mute</opt> <arg>SINK</arg> <arg>1|0</arg></p>
+      <p><opt>set-sink-mute</opt> <arg>SINK</arg> <arg>1|0|toggle</arg></p>
       <optdesc><p>Set the mute status of the specified sink (identified by its symbolic name or numerical index).</p></optdesc>
     </option>
 
     <option>
-      <p><opt>set-source-mute</opt> <arg>SOURCE</arg> <arg>1|0</arg></p>
+      <p><opt>set-source-mute</opt> <arg>SOURCE</arg> <arg>1|0|toggle</arg></p>
       <optdesc><p>Set the mute status of the specified source (identified by its symbolic name or numerical index).</p></optdesc>
     </option>
 
     <option>
-      <p><opt>set-sink-input-mute</opt> <arg>INPUT</arg> <arg>1|0</arg></p>
+      <p><opt>set-sink-input-mute</opt> <arg>INPUT</arg> <arg>1|0|toggle</arg></p>
       <optdesc><p>Set the mute status of the specified sink input (identified by its numerical index).</p></optdesc>
     </option>
 
     <option>
-      <p><opt>set-source-output-mute</opt> <arg>INPUT</arg> <arg>1|0</arg></p>
+      <p><opt>set-source-output-mute</opt> <arg>INPUT</arg> <arg>1|0|toggle</arg></p>
       <optdesc><p>Set the mute status of the specified source output (identified by its numerical index).</p></optdesc>
     </option>